PT type
 
PT10-1ZHO1S
PT15-1ZHO1S
PT22-1ZHO1S
PT22-1ZHO2S
Connection diagrams
 
H.1
H.3
Standard
 
TCVN 6097-1995; IEC-60186; IEC60044-2
Rated voltage / Power frequency withstand voltage / Impulse withstand voltage [1,2/50µs]
kV
6/22/60 (PT10-1ZHO…)
10/28/75 (PT10-1ZHO…)
15/38/95 (PT15-1ZHO…)
24/50/125 (PT22-1ZHO…)
6/24/75 (PT10-1ZHO…)
10/40/95 (PT10-1ZHO…)
15/50/110 (PT15-1ZHO…)
24/60/125 (PT22-1ZHO…)
Number of phase
 
1
Rated frequency
Hz
50
Rated voltage factor
 
1.2 x Un Continuos time
Number of bushing
 
2
Burden
 
50VA
75VA
100VA
150VA
200VA
300VA
Number of primary inputs for rated voltage
 
1 or 2
Service type
 
Outdoor
Creepage distance
mm/kV
25
Outer dimensions
mm
See drawing
Weight
Kg
66
 
 
Rated primary voltage
1 ratio
6000:√3; 6300:√3; 6600:√3; 10000:√3; 10500:√3; 11000:√3; 15000:√3; 22000:√3; 22000:√3
                                     8400            8660             12000               12600         12700
Rated primary voltage
2 ratios
8400/12000
8400/12600
8400/12700
8660/12600
(22000-15000)
:√3
(22000-10000)
:√3
(22000-6000)
:√3
Rated secondary voltage
100; 110; 120; 190; 220; 230; 240; 360
Tolerance of rated secondary voltage
±10%

 
 
Description
Unit
Data
PT type
 
PT22-1ZHI1
PT22-1ZHI1P
Connection diagrams
 
H.1
H.5
Standard
 
TCVN 6097-1995; IEC-60186; IEC60044-2
Rated voltage / Power frequency withstand voltage / Impulse withstand voltage BIL[1,2/50µs]
kV
22/50/95 (PT22-1ZHI1…)
 
24/60/125 (PT22-1ZHI1…)
Number of phase
 
1
Rated frequency
Hz
50
Rated voltage factor
 
1.9 x Un (8h)
Number of bushing
 
1
Burden
 
30VA-0.5
50VA-0.5
Number of primary inputs for rated voltage
 
1
Service type
 
Indoor
Creepage distance
mm/kV
25
Outer dimensions
mm
See drawing
Weight
Kg
35
 
 
Rated primary voltage
1 ratio
6000
6300
7200
10000
11000
14400
15000
22000
Rated primary voltage
2 ratios
22000:√3-15000
22000-15000
22000:√3-10000
22000-10000
22000:√3-6000
22000-6000
Rated secondary voltage
100; 110; 120; 190; 220; 230; 240
Tolerance of rated secondary voltage
±10%
 

 

Description
Unit
Data
PT type
 
PT22-1ZHO2S
Connection diagrams
 
H.6
Standard
 
TCVN 6097-1995; IEC-60186; IEC60044-2
Rated voltage / Power frequency withstand voltage / Impulse withstand voltage BIL[1,2/50µs]
kV
15/38/95
24/50/125
 
15/50/110
24/60/125
Number of phase
 
1
Rated frequency
Hz
50
Rated voltage factor
 
1.9 x Un (8h)
Number of bushing
 
1
Burden
 
300VA
500VA
1000VA
1200VA
Number of primary inputs for rated voltage
 
2
Service type
 
Outdoor
Creepage distance
mm/kV
25
Outer dimensions
mm
See drawing
Weight
Kg
74
 
 
Rated primary voltage
8400-12000
8400-12600
8400-12700
8660-12700
(22000-15000)
:√3
(22000-10000)
:√3
(22000-6000)
:√3
 
Rated secondary voltage
100; 110; 120; 190; 220; 230; 240; 360
Tolerance of rated secondary voltage
±10%

 