Product Detail

 

SPECIFICATION:
 
 
 
 
Description
Unit
Data
CT type
 
PT10-1ZHO1
PT15-1ZHO1
PT22-1ZHO1
PT10-1ZHO1TCS
PT15-1ZHO1TCS
PT22-1ZHO1TCS
PT10-1ZHO2
PT15-1ZHO2
PT22-1ZHO2
PT10-1ZHO2TCS
PT15-1ZHO2TCS
PT22-1ZHO2TCS
PT10-1ZHO1P
PT15-1ZHO1P
PT22-1ZHO1P
PT10-1ZHO1M
PT15-1ZHO1M
PT22-1ZHO1M
Connection diagrams
 
H.1
H.2
H.3
Standard
 
TCVN 6097-1995; IEC-60186; IEC60044-2
Rated voltage / Power frequency withstand voltage / Impulse withstand voltage BIL[1,2/50µs]
kV
6/22/60 (PT10-1ZHO…)
10/28/75 (PT10-1ZHO…)
15/38/95 (PT15-1ZHO…)
24/50/125 (PT22-1ZHO…)
6/24/75 (PT10-1ZHO…)
10/40/95 (PT10-1ZHO…)
15/50/110 (PT15-1ZHO…)
24/60/125 (PT22-1ZHO)
Number of phase
 
1
Rated frequency
Hz
50
Rated voltage factor
 
1.9 x Un (8h)
Number of bushing
 
1
Burden - Measuring Accuracy class
 
25VA-0.5 30VA-0.5 50VA-0.5 75VA-0.5 100VA-0.5 120VA 150VA-0.5
Burden - Protection Accuracy class
 
50VA/3P
75VA/3P
100VA/3P
200VA/3P
Number of primary inputs for rated voltage
 
1 or 2
Service type
 
Outdoor
Creepage distance
mm/kV
25
Outer dimensions
mm
See drawing
Weight
Kg
52
 
 
Rated primary voltage (V)
6000:√3
6300:√3
6600:√3
10000:√3
10500:√3
11000:√3
15000:√3
22000:√3
22900:√3
Rated primary voltage (V)
8400
12000
12600
12700
8400/12000
8400/12600
8400/12700
Rated secondary voltage
Measuring core
100:√3; 110:√3; 190:√3; 100; 110; 120; 190 60/120
Protective core
100:3 ; 110:3 ; 190:3
Product have rated secondary voltage ≥ 100V
 
 
Description
Unit
Data
CT type
 
PT10-1HO1
PT15-1HO1
PT22-1HO1
PT10-1HO1TCS
PT15-1HO1TCS
PT22-1HO1TCS
PT10-1HO2
PT15-1HO2
PT22-1HO2
PT10-1HO2TCS
PT15-1HO2TCS
PT22-1HO2TCS
Connection diagrams
 
H.2
H.4
Standard
 
TCVN 6097-1995; IEC-60186; IEC60044-2
Rated voltage / Power frequency withstand voltage / Impulse withstand voltage BIL[1.2/50µs]
kV
6/22/60 (PT10-1HO…)
10/28/75 (PT10-1HO…)
15/38/95 (PT15-1HO…)
24/50/125 (PT22-1HO…)
6/24/75 (PT10-1HO…)
10/40/95 (PT10-1HO…)
15/50/110 (PT15-1HO…)
24/60/125 (PT22-1HO)
Number of phase
 
1
Rated frequency
Hz
50
Rated voltage factor
 
1.2 x Un continuos time
Number of bushing
 
2
Burden - Measuring Accuracy class
 
50VA-0.5               75VA-0.5                 100VA-0.5            150VA-0.5
Burden - Protection Accuracy class
 
50VA/3P
75VA/3P
100VA/3P
200VA/3P
Number of primary inputs for rated voltage
 
1 or 2
Service type
 
Outdoor
Creepage distance
mm/kV
25
Outer dimensions
mm
See drawing
Weight
Kg
66

 

Rated primary voltage (V)
6000
6300
6600
7200
10000
11000
14400
15000
20000
22000
24000
Rated primary voltage (V)
100; 110; 120; 190
Rated secondary voltage
60/120

 

 

 

Description
Unit
Data
CT type
 
PT22-1ZHO2
PT22-1ZHO2P
Connection diagrams
 
H.6
H.8
Standard
 
TCVN 6097-1995; IEC-60186; IEC60044-2
Rated voltage / Power frequency withstand voltage / Impulse withstand voltage BIL[1.2/50µs]
kV
15/38/95
(Rated primary voltage 15kV)
24/50/125
(Rated primary voltage 24kV)
15/50/110
(Rated primary voltage 15kV)
24/60/125
(Rated primary voltage 24kV)
Number of phase
 
1
Rated frequency
Hz
50
Rated voltage factor
 
1.9 x Un (8h)
Number of bushing
 
1
Burden - Measuring Accuracy class
 
50VA-0.5; 75VA-0.5; 100VA-0.5; 120VA-0.5; 150VA-0.5
Burden - Protection Accuracy class
 
75VA/3P
100VA/3P
200VA/3P
200VA/6P
Number of primary inputs for rated voltage
 
2
Service type
 
Outdoor
Creepage distance
mm/kV
25
Outer dimensions
mm
See drawing
Weight
Kg
74

 

Rated primary voltage 2 ratios(V)        
8400-12000; 8400-12600; (11000-22000):√3; (15000-22000):√3
Rated secondary voltage
Measuring core
 
Protective core
 
 
 
Description
Unit
Data
CT type
 
PT35-1ZHO1
PT35-1ZHO2
PT35-1ZHO1P
PT35-1ZHO1M
Connection diagrams
 
H.1
H.3
H.5
Standard
 
TCVN 6097-1995; IEC-60186; IEC60044-2
Rated voltage / Power frequency withstand voltage / Impulse withstand voltage BIL[1.2/50µs]
kV
35/70/170 (PT35-1ZHO…)
Number of phase
 
1
Rated frequency
Hz
50
Rated voltage factor
 
1.9 x Un (8h)
Number of bushing
 
1
Burden - Measuring Accuracy class
 
50VA-0.5
75VA-0.5
100VA-0.5
Burden - Protection Accuracy class
 
75VA/3P
200VA/3P
200VA/6P
Number of primary inputs for rated voltage
 
1 or 2
Service type
 
Outdoor
Creepage distance
mm/kV
25
Outer dimensions
mm
See drawing
Weight
Kg
70
 
Rated primary voltage
1 ratio (V)
8400-12000; 8400-12600; (11000-22000):√3; (15000-22000):√3
Rated primary voltage
2 ratios (V)
 (22000-35000): √3 [burden: 30/50VA or 50/75VA]
Rated secondary voltage
Measuring core
100: √3; 110:√3; 190: √3; 100; 110; 120; 190
Protective core
100:3; 110:3; 190:3
 
 
Description
Unit
Data
CT type
 
PT35-1HO1
PT35-1HO1TCS
Connection diagrams
 
H.2
Standard
 
TCVN 6097-1995; IEC-60186; IEC60044-2
Rated voltage / Power frequency withstand voltage / Impulse withstand voltage BIL[1.2/50µs]
kV
35/70/170 (PT35-1HO…)
Number of phase
 
1
Rated frequency
Hz
50
Rated voltage factor
 
1.2 x Un continuous time
Number of bushing
 
2
Burden - Measuring Accuracy class
 
30VA-0.5
50VA-0.5
Number of primary inputs for rated voltage
 
1
Service type
 
Outdoor
Creepage distance
mm/kV
25
Outer dimensions
mm
See drawing
Weight
Kg
115
 
Rated primary voltage 1 ratio (V)
30000
31500
33000
34500
35000
36000
38500
Rated secondary voltage (V)
100; 110; 120; 190

 

 

Allied Companies

  • EMIC
  • HEM
  • CADIVI
  • CTBT
  • THIBIDI
  • EPT
  • VIHEM
  • VINAKIP
  • CFT
  • HPMC