Product Detail

 

SPECIFICATION:

 

Description
Unit
Data
CT type
 
PT22-1ZHOD1
PT22-1ZHOD2
PT22-1ZHOD1P
Connection diagrams
 
H.1
H.3
H.5
Standard
 
TCVN 6097-1995; IEC-60186; IEC60044-2
Rated voltage / Power frequency withstand voltage / Impulse withstand voltage BIL[1.2/50µs]
kV
24/60/125 (PT22-1ZHOD…)
Number of phase
 
1
Rated frequency
Hz
50
Rated voltage factor
 
1.9 x Un (8h)
Number of bushing
 
1
Burden - Measuring Accuracy class
 
50VA-0.5
75VA-0.5
100VA-0.5
Burden - Protection Accuracy class
 
50VA/3P
75VA/3P
100VA/3P
120VA/3P
200VA/3P
200VA/6P
Number of primary inputs for rated voltage
 
1 or 2
Service type
 
Outdoor
Creepage distance
mm/kV
25
Outer dimensions
mm
See drawing
Weight
Kg
93

 

Rated primary voltage
1 ratio (V)
20000:√3
22000:√3
22900:√3
24000:√3
Rated primary voltage
2 ratios (V)
 (15000-22000) :√3 [burden:30/50VA or 50/75VA]
Rated secondary voltage
Measuring core
100:√3; 110:√3; 190:√3; 100; 110; 120; 190
Protective core
100:3 ; 110:3 ; 190:3

 

 

Description
Unit
Data
CT type
 
PT22-1HOD1
PT22-1HOD2
Connection diagrams
 
H.2
H.4
Standard
 
TCVN 6097-1995; IEC-60186; IEC60044-2
Rated voltage / Power frequency withstand voltage / Impulse withstand voltage BIL[1,2/50µs]
kV
24/50/125 (PT22-1HOD…)
 
Number of phase
 
1
Rated frequency
Hz
50
Rated voltage factor
 
1.2 x Un continuos time
Number of bushing
 
2
Burden - Measuring Accuracy class
 
75VA-0.5
100VA-0.5
120VA-0.5
150VA-0.5
250VA-1
600VA-3
 
Number of primary inputs for rated voltage
 
1 hoặc 2
 1 or 2
Service type
 
Outdoor
Creepage distance
mm/kV
25
Outer dimensions
mm
See drawing
Weight
Kg
111

 

Rated primary voltage
1 ratio (V)
20000
22000
22900
24000
Rated primary voltage
2 ratios (V)
 (15000-22000) :√3 [burden:30/50VA or 50/75VA]
Rated secondary voltage (V)
100; 110; 120; 190

 

 

Description
Unit
Data
CT type
 
PT35-1ZHOD1
PT35-1ZHOD2
PT35-1ZHOD1P
Connection diagrams
 
H.1
H.3
H.5
Standard
 
TCVN 6097-1995; IEC-60186; IEC60044-2
Rated voltage / Power frequency withstand voltage / Impulse withstand voltage BIL[1.2/50µs]
kV
35/70/170 (PT35-1ZHOD…)
Number of phase
 
1
Rated frequency
Hz
50
Rated voltage factor
 
1.9 x Un (8h)
Number of bushing
 
1
Burden - Measuring Accuracy class
 
50VA-0.5
75VA-0.5
100VA-0.5
Burden - Protection Accuracy class
 
50VA/3P
75VA/3P
100VA/3P
120VA/3P
200VA/3P
200VA/6P
Number of primary inputs for rated voltage
 
1 or 2
Service type
 
Outdoor
Creepage distance
mm/kV
25
Outer dimensions
mm
See drawing
Weight
Kg
95

 

Rated primary voltage
1 ratio (V)
30000: √3
31500: √3
33000: √3
34500: √3
35000: √3
38500: √3
Rated primary voltage
2 ratios (V)
 (22000-35000) :√3 [burden:30/50VA or 50/75VA]
Rated secondary voltage (V)
Measuring core
100: √3; 110: √3; 190: √3; 100; 110; 120; 190
Protective core
100:3 ; 110:3 ; 190:3

 

 

 

Description
Unit
Data
CT type
 
PT35-1HOD1
PT35-1HOD2
Connection diagrams
 
H.2
H.4
Standard
 
TCVN 6097-1995; IEC-60186; IEC60044-2
Rated voltage / Power frequency withstand voltage / Impulse withstand voltage BIL[1,2/50µs]
kV
35/70/170 (PT35-1HOD…)
Number of phase
 
1
Rated frequency
Hz
50
Rated voltage factor
 
1.2 x Un Continuous time
Number of bushing
 
2
Burden - Measuring Accuracy class
 
75VA-0.5
100Va-0.5
120VA-0.5
150VA-0.5
250VA-1
600VA-3
Number of primary inputs for rated voltage
 
1 or 2
Service type
 
Outdoor
Creepage distance
mm/kV
25
Outer dimensions
mm
See drawing
Weight
Kg
115

 

Rated primary voltage 1 ratio (V)
30000
31500
33000
34500
35000
36000
38500
Rated primary voltage 2 ratios (V)
 (22000-35000): √3 [burden: 30/50VA or 50/75VA]
Rated secondary voltage
100; 110; 120; 190

 

 

Allied Companies

  • EMIC
  • HEM
  • CADIVI
  • CTBT
  • THIBIDI
  • EPT
  • VIHEM
  • VINAKIP
  • CFT