PVC insulated wires and cords

CADIVI

 

General 

PVC insulated wires are used for indoor electrical appliances .

Applied Standards

 According to customer’s requirements ,  CADIVI is able to manufacture  :

* Solid wire up to 660 V comply with TCVN 2103-1994

 Designation : VC for Copper wire and VA for Aluminum wire

Flexible wires and cords up to 250 V comply with TCVN 2103-1994 .

  • Designation : VCm for flexible copper wire 
  • Designation : VCmd for flat, non-sheathed cord
  • Designation : VCmx for twist, non-sheathed cord
  • Designation : VCmt for circular, sheathed cord
  • Designation : VCmo for oval, sheathed cord
  • Designation : VCmod for flat-oval, sheathed cord

         

 

VC - 450/750 V: TCVN 6610-3

Nominal area

Contruction

Conductor diameter *

 Insulation thickness

Overall diameter *

Weight *

DC resistance at 20o

mm2

No/mm

mm

mm

mm

kg/km

W/km

1,5

1/1,38

1,38

0,7

2,78

20,63

12,1

2,5

1/1,77

1,77

0,8

3,37

32,23

7,41

4,0

1/2,24

2,24

0,8

3,84

47,30

4,61

6,0

1/2,74

2,74

0,8

4,34

66,71

3,08

10

1/3,56

3,56

1,0

5,56

111,51

1,83

 

VCm - 300/500 V: TCVN 6610-3

Nominal area

Contruction

Conductor diameter *

  Insulation thickness

Overall diameter *

   Weight *

DC resistance at 20o

mm2

No/mm

mm

mm

mm

kg/km

W/km

0,5

16/0,20

0,92

0,6

2,12

8,84

39,0

0,75

24/0,20

1,13

0,6

2,33

11,75

26,0

1,0

32/0,20

1,31

0,6

2,51

14,48

19,5

 

VCm - 450/750 V: TCVN 6610-3

Nominal area

 Contruction

Conductor diameter *

  Insulation thickness

  Overall diameter *

           Weight *

DC resistance at 20o

mm2

No/mm

mm

mm

mm

kg/km

W/km

1,5

30/0,25

1,58

0,7

2,98

20,88

13,3

2,5

50/0,25

2,04

0,8

3,64

32,93

7,98

4,0

56/0,30

2,59

0,8

4,19

48,66

4,95

6,0

7 x (12/0,30)

3,17

0,8

4,77

69,07

3,30

10

7 x (12/0,40)

4,23

1,0

6,23

120,86

1,91

16

7 x (18/0,40)

5,18

1,0

7,18

173,29

1,21

25

7 x (28/0,40)

6,46

1,2

8,86

266,30

0,780

35

7 x (40/0,40)

7,72

1,2

10,12

368,28

0,554

50

19 x (21/0,40)

9,22

1,4

12,02

522,73

0,386

70

19 x (19/0,50)

10,96

1,4

13,76

722,30

0,272

95

19 x (25/0,50)

12,58

1,6

15,78

948,80

0,206

120

19 x (32/0,50)

14,23

1,6

17,43

1196,42

0,161

150

37 x (21/0,50)

16,08

1,8

19,68

1536,30

0,129

185

37 x (25/0,50)

17,55

2,0

21,55

1831,78

0,106

240

61 x (20/0,50)

20,15

2,2

24,55

2405,27

0,0801

* Approximate values

VCmo - 300/500 V: TCVN 6610-5

   Nominal area

Contruction

Conductor diameter *

 Insulation thickness

 Sheath thickness

Out side dimension *

            Weight *

 DC resistance at 20oC

mm2

No/mm

mm

mm

mm

mm

kg/km

W/km

0,75

24/0,20

1,13

0,6

0,8

3,93 x 6,26

42,26

26,0

1,0

32/0,20

1,31

0,6

0,8

4,11 x 6,62

49,05

19,5

1,5

30/0,25

1,58

0,7

0,8

4,58 x 7,56

65,53

13,3

2,5

50/0,25

2,04

0,8

1,0

5,64 x 9,28

102,17

7,98

* Approximate values

 

Allied Companies

  • EMIC
  • HEM
  • CADIVI
  • CTBT
  • THIBIDI
  • EPT
  • VIHEM
  • VINAKIP
  • CFT
  • HPMC